solar flame ASL series
Solar Flame ASL series
Model ASL is a superior flat plate collector encasing harp type absorber with very high efficiency level. It is best suited for closed loop /natural or forced circulation systems, small or large scale, great choice for mild and colder climates, where its great insulation properties are desired for minimizing thermal losses and maximizing efficiency. This collector has been tested in NSCR DEMOKRITOS laboratory in Greece and is certified with SOLAR KEYMARK.
The ASL series of collectors is used in the ABL certified series of solar water heaters, the most powerful solar water heaters in the Greek market and among the most powerful worldwide (source: solar Keymark database, 10/2021)
|
Standard solution - with normal shaped headers | ||
![]() | ||
A. Row outlet to circulator | B. Parallel connection | |
![]() | ![]() | |
C. Series connection | D. Row inlet from circulator | |
![]() | ![]() |
Optional solution - Fast connections kit with special shaped headers | ||
![]() | ||
A. Row outlet to circulator | B. Parallel connection | |
![]() | ![]() | |
C. Series connection | D. Row inlet from circulator | |
![]() | ![]() |
Steel supports | ||
| ||
1.a One collector on flat roof | 1.b One collector on sloped roof | |
![]() | ![]() | |
2.a Two collectors on flat roof | 2.b Two collectors on sloped roof | |
![]() | ![]() | |
3.a Three collectors on flat roof | 3.b Three collectors on sloped roof | |
![]() | ![]() |
Aluminum frame supports | ||
| ||
1.a One collector on flat roof | 1.b One collector on sloped roof | |
![]() | ![]() | |
2.a Two collectors on flat roof | 2.b Two collectors on sloped roof | |
![]() | ![]() |
Model | 1.50 V | 1.82 V | 2.00 V | 2.37 V | 2.72 V | |||||
Gross area [m²] | 1.50 | 1.82 | 2.00 | 2.37 | 2.72 | |||||
Total Dimensions [mm] | L:1480 W:1010 H:86 | L:1480 W:1230 H:86 | L:1980 W:1010 H:86 | L:1930 W:1230 H:86 | L:2160 W:1260 H:86 | |||||
Weight empty [kg] | 26.50 | 32.10 | 34.80 | 40.80 | 46.30 | |||||
Max. operating Pressure [bar] | 10 | |||||||||
Thermal Liquid Capacity [lt] | 1.28 | 1.54 | 1.48 | 1.76 | 1.90 | |||||
Collector front Cover-Thickness | LOW IRON TEMPERED GLASS 3.2mm | |||||||||
Insulation | 40mm MINERAL WOOL, λ=0.035 [W/(mK)] | |||||||||
Casing Material | ALUMINUM POWDER COATED | |||||||||
Sealing Materials | POLYURETHANE - SILICON - EPDM | |||||||||
Absorber Area [m²] | 1.38 | 1.72 | 1.86 | 2.23 | 2.57 | |||||
Water-frame type/material/diameter | Harp type, copper, ø22 headers-ø8 risers | |||||||||
Nr. Of risers | 10 | 12 | 10 | 12 | 12 | |||||
Absorber Material-Treatment | ALUMINUM / PVD COATING / HIGH SELECTIVE – A=0.95±0.02 / e=0.05±0.02 | |||||||||
Absorber construction Type | LASER | |||||||||
Heat transfer Medium | GLYCOL + WATER MIXTURE | |||||||||
Tests and Certifications | SOLAR KEYMARK | |||||||||
EFFICIENCY VALUES BASED ON EN ISO 9806:2013 STANDARD (SKM10126.1) | ||||||||||
Efficiency η0,b | 0.784 | |||||||||
Thermal loss a1 [w/(m²K) ] | 3.90 | |||||||||
Thermal loss a2 (w/(m²K² ) | 0.017 | |||||||||
IAM (Κθ at 50°) | 0.93 | |||||||||
Stagnation temp. [°C] | 187 | |||||||||
ηcol | 59% |